Gas Turbine Multi-Core Electric Cable 450°C 600V

February 29, 2016 by Thermal Wire and Cable

Gas Turbine Multi-Core Electric Cable 450°C 600V

These multi-conductor cables are designed for a continuous operation at an ambient temperature range from -40C- +450C. Shielding is available as an option. Class H, flexible stranding, is employed and is of Nickel alloy material minimum nickel percentage 27%, and is oxygen-free high conductivity. Passes Mil-DTL-25038J Wet Dielectric test. Passes Shake and Bake Flame Test under vibration. Reduced diameter construction for installations in space limited areas. Fused PTFE tape design has been created for fluid susceptibility like Skydrol for corrosion purposes.

Learn More

Gas Turbine Single-Core Electric Cable 450°C 600V

February 28, 2016 by Thermal Wire and Cable

Gas Turbine Single-Core Electric Cable 450°C 600V

These single conductor cables are designed for a continuous operation at an ambient temperature range from -40C- +450C. Class H, flexible stranding, is employed and is of Nickel alloy material minimum nickel percentage 27%, and is oxygen-free high conductivity. Passes Mil-DTL-25038J Wet Dielectric test. Passes Shake and Bake Flame Test under vibration. Reduced diameter construction for installations in space limited areas. Fused PTFE tape design has been created for fluid susceptibility like Skydrol for corrosion purposes. Shielding and armor were optional.

Learn More

Gas Turbine Single Conductor Cable 250°C 600V

February 26, 2016 by Thermal Wire and Cable

Gas Turbine Single Conductor Cable 250°C 600V

These single conductor cables are designed for a continuous operation at an ambient temperature range from -40C- +250C. Flexible stranding, is employed and is of Nickel alloy material minimum nickel percentage 50MI, and is oxygen-free, high conductivity. Fused PTFE jacket and primary insulation passes ASTM D975-74 Diesel fuel oils, ASTM D1655-75 Standard Specification for Turbine fuels, ASTM D2880-76 Gas Turbine Fuel Oils, Mil-L-23699 Synthetic Oil, Splashing. A PTFE glass tape is applied for additional cut through resistance.
Reduced diameter construction for installations in space limited areas. Fused PTFE tape design have been designed for fluid susceptibility like skydrol for corrosion purposes.

Learn More

450°C (842°F) Thermal Wire CST 450 Flare Stack Cable up to 25,000VDC Grade III

February 25, 2016 by Thermal Wire and Cable

Products / / 450°C (842°F) Thermal Wire CST 450 Flare Stack Cable up to 25,000VDC Grade III 450°C (842°F) Thermal Wire CST 450 Flare Stack Cable up to 25,000VDC Grade III

CST 450 Grade III Ignition lead wire is designed for flare stacks, blast furnace instrumentation, curing systems, glass fabrication, plastics manufacturing, fuel igniters, and offshore oil rigs.

Learn More

Gas Turbine Multi–Conductor Shielded Cable 200°C 600V

February 25, 2016 by Thermal Wire and Cable

Multi conductor shielded 600V 200C series feature stranded silver-coated copper conductors, extruded PTFE insulation, and overall silver-coated copper braid shield and fused PTFE tape jacket. Manufactured in accordance with SAE-AS 22759/11. These multi conductor cables are designed for a continuous operation at an ambient temperature range from -60C- +200C. An optional PTFE impregnated tape is optional for enhanced cut through. Fused PTFE jacket and primary insulation passes ASTM D975-74 Diesel fuel oils, ASTM D1655-75 Standard Specification for Turbine fuels, ASTM D2880-76 Gas Turbine Fuel Oils, Mil-L-23699 Synthetic Oil, Splashing.

Learn More

250°C (482°F) PTFE Insulated High-Voltage Lead Wire 25,000KVDC

February 24, 2016 by Thermal Wire and Cable

PTFE high voltage ignition cable typical applications include, gas ignitor systems for furnaces, and internal wiring for electronic gas ignitor system.

Learn More

250°C (482°F) SR-250 Silicone Rubber High-Voltage Lead Wire 25,000 VDC

February 23, 2016 by Thermal Wire and Cable

SR-250 Silicone Rubber High-Voltage Lead Wire is used in gas appliance igniter systems.

Learn More

250°C (482°F) Thermal Wire SRGE Flare Stack Cable 10KVAC 25KVdc Grade II

February 22, 2016 by Thermal Wire and Cable

250°C (482°F) Thermal Wire SRGE Flare Stack Cable 10KVAC 25KVdc Grade II

SRGE ignition lead wire is commonly used in flare stacks, blast furnace instrumentation, curing systems, glass fabrication, plastics manufacturing, fuel igniters, offshore oil rigs, etc.

Learn More
  • « Previous Page
  • 1
  • …
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • Next Page »

Latest News

  • Fox News Film
  • Photo Gallery Composite cables
  • Troubleshooting Flare Stack Cable
  • Aircraft Warning Light Cables
  • The need for Armored HEI and Thermocouple Cables

Subscribe to our eNews

  • This field is for validation purposes and should be left unchanged.

Topics

  • Community Involvement
  • Company Updates
  • High-Temperature Cable Solutions
  • Industry News
  • Product Announcements

News

  • Community Involvement (2)
  • Company Updates (13)
  • High-Temperature Cable Solutions (1)
  • Industry News (8)
  • Product Announcements (9)

Contact Information

Thermal Wire and Cable, LLC
5410 Jaeger Rd
Naples, FL 34109

(239) 430-9473

(239) 435-1779

sales@thermalwire.com

© Copyright 2016 Thermal Wire and Cable, LLC / Web Development: Pauli Systems, LC · All Rights Reserved ·